Model: BWD 01 R

Model: BWD 02 PR

Model: BWD 03 W

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 















The grass is always greener on your side.
WaterCube – enjoy the luxury of your own water supply The WaterCube is the ideal way of setting up a new, independent water supply, or addressing problems with existing water supply systems, if you live in coastal areas or on islands with a limited fresh water supply.



Product Specifications
Specifications :
Number of membranes 3
Membrane DOW Filmtec SWRO 3x21”
Power consumption* 720 W
Water production* approx 4800 l/day (1270 GPD**)
*Design parameter: Output 200 l/h, 3 phases 400 Volt 50 Hz, 25 C sea water at 35.000 TDS +/- 15%
** Measured in US Gallons
   
Connections :
Electrical specifications 3 phases 230 V 50/60 Hz
3 phases 400 V 50/60 Hz
1 phase 110V/230V 50/60 Hz w/Danfoss VFD/VLT only
Feed water inlet* Ø 19mm
Fresh water flush inlet Ø 19mm
Brine outlet Ø 19mm
Permeate outlet Ø 19mm
* Pipe connections: All measurements are internal diameters
   
Operating limits :
Feed water temperature 5 – 45 C (41 – 113 F )
Ambient temperature 5 – 45 C (41 – 113 F )
Feed pressure 2 – 5 bar ( 29 – 72 PSI )
Fresh water flush pressure 2 – 5 bar ( 29 – 72 PSI )
Minimum feed water flow 1.2 m3/h (5.3 GPM )
Minimum fresh water flush flow 1.2 m3/h (5.3 GPM )
Maximum pressure drop permeate line 0.2 bar (2.9 PSI )
   
Feed water requirements* :
Total dissolved solids (TDS) 15000 – 50000 mg/l
SDI rating (15 min.) < 3 SDI
Turbidity < 1 NTU
Free chlorine/total chlorine < 0.1 mg/l
Total Organic Carbon (TOC) < 3 mg/l
Hydrocarbons or silicone based oils < 0.1 mg/l
Ferrous iron < 4 mg/l (pH <6, oxygen <0.05 mg/l)
Ferric iron < 0.05 mg/l
Manganese < 0.05 mg/l
Aluminium < 0.05 mg/l
Dissolved air < 8 mg/l, measured as O2
   
* For this purpose 1 mg/litre = 1 ppm.If feed water is outside of the range, additional pre treatment is required.
In general, the unit will be able to process water of ‘normal’ sea water quality
   
Fresh water requirements* (for fresh water flush of the system) :
Free chlorine/total chlorine < 0.1 mg/l
Total dissolved solids (TDS) < 600 mg/l
*1 mg/litre = 1 ppm.  
   
Typical Water Quality Produced
Parameter
Units
Value
EU Standards
US standards
Total hardness mg CaCo3/l 22 - -
Total alkalinity mg CaCo3/l 17 - -
Suspended solids mg/l < 0.1 - 250
Conductivity μSiemens/cm 690 2500 -
Nitrate as N mg NO3-N/l <0.002 50 10
Nitrite as N mg NO2-N/l <0.003 0.50 1
Fluoride mg F-/l 0.007 1.5 2.0
Turbidity NTU <0.05 - -
Chloride mg Cl-/l 191 250 250
Sulphate mg SO4 2-/l 2.4 250 -
Aluminium mg/l 0.028 0.2 0.2
Sodium mg/l 132 250 -
Potassium mg/l 2.31 - -
Magnesium mg/l 7.74 - -
Calcium mg/l 3.94 - -
True colour PtCo units <5 - -
Copper mg/l <0.007 2.0 1.0
Iron mg/l 0.028 0.2 0.3
Manganese mg/l <0.005 0.05 -
Zinc mg/l <0.002 - 5
         
Total coliforms MPN/100ml <1 0 0
e-coli MPN/100ml <1 0 0
         
Note: Results by Wide Bay Water Corporation, 29-31 Ellengowan St., Urangan, QLD, Australia
         
Analyses on other parameters may be issued from time to time.
Site Terms  |  Terms and Conditions of Sale  |  Privacy Policy  |  About Us  |  Contact Us